HiLetgo- W1209 12V DC Digital Temperature Controller Board Micro Digital Thermostat -50-110°C Electronic Temperature Temp Control Module Switch with 10A One-channel Relay and Waterproof
- 100% complete machine patch, wave soldering, stable performance, good consistency.
- Embedded CPU chip (MCU), more intelligent, lower power consumption.
- Automatic power set memory (MCU built-in EEPROM memory unit).
- Control accuracy of 0.1 degrees Celsius. Have been tested for stability, consistency and reliability.
- Tips: – long press set to get menu, starts at P0 – press +/- to get next P-parameter – press set to choose that parameter – press +/- to select the value you want for that parameter – press set to accept it – long press +/- = reset to default – power-out does reset to default – default temp set is 34.5C
Specifications:
Model: W1209
Dimensions: 48.5 * 40mm
Temperature Control mode: ON / OFF
Temperature Range :-50 – 110 degree centigrade
Resolution: When temperature is 0.1 degree, the resolution is -9.9~99.9, other temperature segment is 1 degree.
Control Accuracy: 0.1 degree
Hysteresis Accuracy: 0.1 degree
Refresh Rate: 0.5s
High Temperature Protection 0 – 110 degree centigrade
Supply Voltage: DC 12V
Static Current: Less than 35MA, attract current less than 65MA
Output Voltage: DC 12V
Output Power: 20A relay
Measurement Input: NTC (10K 0.5%) Waterproof Sensor
Environmental Requirements: -10 – 60 degree centigrade; Humidity 20% – 85%
Instructions for use:
Connect the power supply and equipment, the measuring temperature is displayed,
press the “SET” button, press ” + or – ” to set the desired temperature (long press ” + or – ” to quickly increase or decrease),
press “SET” to confirm the setting and return, controller automatically performs the relay ON/OFF.
the thermostat output is 10A relay, meet a variety of high-power loads. LED Indicator: LED off indicates the relay off; Lighting, indicates the relay is closed.
Digital LED Tubes: “LL” indicates sensor open, “HH” indicates overrange, the relay will be forcibly disconnected; “—” indicates high temperature alarm
Long press the “SET” button to enter the main menu settings,
press ” + or – ” to switching between P0-P6,
then long press “SET” or 10 seconds without keystrokes to confirm the setting and return.